ebus: Revision 8
Vaillant
serial port on boilerhttp://www.ab-log.ru/smart-house/heating-automation/vaillant-rs232 5V TTL level serial but it also accepts 3.3V serial (tested with CP2102 which is 3.3V, but 5V tolerant)
1 Not used Serial port is 9600 8N1 This is translated and extended version of protocol dump from link above to ease comparison with my boiler
The first line - that we send, the second - the answer of the boiler. Something like initialize the connection. # 07 02 00 00 00 04 C4 # 08 00 00 9E 0A 0C 6B FD 08 00 00 93 0B 09 FB 0B Minimum design flow temperature # 07 00 00 00 C2 01 7C # 04 00 [# 23] 33 35 degrees Start hysteresis # 07 00 00 00 C3 01 7E # 04 00 [# 02] 12 2 ° Hysteresis off # 07 00 00 00 C4 01 70 # 04 00 [# 06] 16 6 ° Left before the service # 07 00 00 00 AC 02 A3 # 05 00 [# 0B C2] #FC 3010 hours Maximum temp filing for DHW # 07 00 00 00 A6 01 B4 # 04 00 [# 55] 45 85 degrees Maximum time the boiler heating # 07 00 00 00 66 01 2D # 04 00 [# 2D] 3D 45 degrees Adjusting the outer t-pair (if connected to the boiler sensor outdoor t-ry) # 07 00 00 00 65 01 2B # 04 00 [# 00] 10 0 degrees Maximum design temp boiler # 07 00 00 00 E1 01 3A # 04 00 [# 46] 56 70 degrees Pump run after the end of heating (after turning off the burners) # 07 00 00 00 64 01 29 # 04 00 [# 1E] 0E 30 minutes Collector temperature (if also the boiler sensor is connected) # 07 00 00 00 B8 02 8B # 06 00 00 00 00 60 0 degrees Maximum flow temperature heating (in my case only the range of 60 to 83 degrees) # 07 00 00 00 A5 01 B2 # 04 00 [# 52] 42 82 degrees Vrebya pump run after turning off the boiler # 07 00 00 00 63 01 27 # 04 00 [# 12] 02 18 (180) Shifting values hotstart # 07 00 00 00 9D 01 C2 # 04 00 07 17 7 Partial heat. Boiler # 07 00 00 00 A9 01 AA # 04 00 [# 01] 11 1 kW Hours on GVS # 07 00 00 00 22 02 A6 # 05 00 00 00 28 0 Cycles of heating # 07 00 00 00 29 02 B0 # 05 00 00 [# 2B] 03 43 Cycles DHW # 07 00 00 00 23 02 A4 # 05 00 00 00 28 0 There is a feedback controller # 07 00 00 00 74 01 09 # 04 00 00 10 0 (OFF) Status signal DCF # 07 00 00 00 69 01 33 # 04 00 00 10 0 (no reception) VUV Mittenstellung # 07 00 00 00 45 01 6B # 04 00 00 10 0 (OFF) Counter 3 ignition attempts # 07 00 00 00 6F 01 3F # 04 00 0A 1A 10 Unsuccessful automatic ignition # 07 00 00 00 1F 01 DF # 04 00 0A 1A 10 Number of trips thermal protection # 07 00 00 00 20 01 A1 # 04 00 00 10 0 Outdoor temperature # 07 00 00 00 6A 03 37 # 06 00 FC 39 AA 63 -60.44 T-pa boiler SC down # 07 00 00 00 B6 02 97 # 06 00 FF 21 AA 5F -13.94 T ra feed # 07 00 00 00 18 03 D3 # 06 00 01 76 00 88 23.38 / no errors Start the timer by GVL # 07 00 00 00 71 01 03 # 04 00 01 11 1 (ON) Mode # 07 00 00 00 08 01 F1 # 04 00 01 11 1 (winter) Request to heat DHW C1 / C2 # 07 00 00 00 58 01 51 # 04 00 00 10 0 (OFF) Ionisation current # 07 00 00 00 73 02 04 # 05 00 FC EC 25 64748.00 Circulation pump for boiler layered # 07 00 00 00 E0 01 38 # 04 00 00 10 0 (OFF) Pumps UK # 07 00 00 00 DF 01 46 # 04 00 00 10 0 (OFF) The circulation pump # 07 00 00 00 AF 01 A6 # 04 00 00 10 0 (OFF) Pump heating boiler # 07 00 00 00 01 9E C4 # 04 00 00 10 0 (OFF) External heating pump # 07 00 00 00 3F 01 9F # 04 00 00 10 0 (OFF) Built-in pump # 07 00 00 00 44 01 69 0 (OFF) Calc. temp an external regulator 7-8-9 # 07 00 00 00 25 02 A8 # 05 00 05 A0 82 90,00 Room thermostat # 07 00 00 00 01 0E FD # 04 00 00 10 0 (OFF) The design temperature of the boiler # 07 00 00 00 04 02 EA # 05 00 00 F0 D8 15 degrees The calculated flow temperature, the handle on the panel # 07 00 00 00 19 02 D0 # 05 00 02 30 1C 35 degrees The temperature of the boiler # 07 00 00 00 17 03 CD # 06 00 FF 21 AA 5F -13.94 Degrees The flow sensor HS # 07 00 00 00 16 03 CF # 06 00 FF 21 AA 5F -13.94 Record the values in the boiler: The second byte is 0x80 The fifth byte - Register Sixth byte - value Seventh - CRC (checksum) Example, set the value of the pump run - 31 minutes (value 0x1F) Register 0x64 # 07 80 00 00 64 1F FF If all goes well, the boiler will return the following sequence. # 03 00 06 |