Dobrica Pavlinušić's random unstructured stuff
ebus: Revision 4
Vaillant
serial port on boilerhttp://www.ab-log.ru/smart-house/heating-automation/vaillant-rs232 5V TTL level serial
1 Not used The first line - that we send, the second - the answer of the boiler. In parentheses is the value that we get. Something like initialize the connection. # 07 # 02 # 00 # 00 # 00 # 04 # C4 # 08 # 00 # 00 # 9E # 0A # 0C # 6B # FD Minimum design flow temperature # 07 # 00 # 00 # 00 # C2 # 01 # 7C # 04 # 00 [# 23] # 33 35 degrees Start hysteresis # 07 # 00 # 00 # 00 # C3 # 01 # 7E # 04 # 00 [# 02] # 12 2 ° Hysteresis off # 07 # 00 # 00 # 00 # C4 # 01 # 70 # 04 # 00 [# 06] # 16 6 ° Left before the service # 07 # 00 # 00 # 00 # AC # 02 # A3 # 05 # 00 [# 0B # C2] #FC 3010 hours Maximum temp filing for DHW # 07 # 00 # 00 # 00 # A6 # 01 # B4 # 04 # 00 [# 55] # 45 85 degrees Maximum time the boiler heating # 07 # 00 # 00 # 00 # 66 # 01 # 2D # 04 # 00 [# 2D] # 3D 45 degrees Adjusting the outer t-pair (if connected to the boiler sensor outdoor t-ry) # 07 # 00 # 00 # 00 # 65 # 01 # 2B # 04 # 00 [# 00] # 10 0 degrees Maximum design temp boiler # 07 # 00 # 00 # 00 # E1 # 01 # 3A # 04 # 00 [# 46] # 56 70 degrees Pump run after the end of heating (after turning off the burners) # 07 # 00 # 00 # 00 # 64 # 01 # 29 # 04 # 00 [# 1E] # 0E 30 minutes Collector temperature (if also the boiler sensor is connected) # 07 # 00 # 00 # 00 # B8 # 02 # 8B # 06 # 00 # 00 # 00 # 00 # 60 0 degrees Maximum flow temperature heating (in my case only the range of 60 to 83 degrees) # 07 # 00 # 00 # 00 # A5 # 01 # B2 # 04 # 00 [# 52] # 42 82 degrees Vrebya pump run after turning off the boiler # 07 # 00 # 00 # 00 # 63 # 01 # 27 # 04 # 00 [# 12] # 02 18 (180) Shifting values hotstart # 07 # 00 # 00 # 00 # 9D # 01 # C2 # 04 # 00 # 07 # 17 7 Partial heat. Boiler # 07 # 00 # 00 # 00 # A9 # 01 # AA # 04 # 00 [# 01] # 11 1 kW Hours on GVS # 07 # 00 # 00 # 00 # 22 # 02 # A6 # 05 # 00 # 00 # 00 # 28 0 Cycles of heating # 07 # 00 # 00 # 00 # 29 # 02 # B0 # 05 # 00 # 00 [# 2B] # 03 43 Cycles DHW # 07 # 00 # 00 # 00 # 23 # 02 # A4 # 05 # 00 # 00 # 00 # 28 0 There is a feedback controller # 07 # 00 # 00 # 00 # 74 # 01 # 09 # 04 # 00 # 00 # 10 0 (OFF) Status signal DCF # 07 # 00 # 00 # 00 # 69 # 01 # 33 # 04 # 00 # 00 # 10 0 (no reception) VUV Mittenstellung # 07 # 00 # 00 # 00 # 45 # 01 # 6B # 04 # 00 # 00 # 10 0 (OFF) Counter 3 ignition attempts # 07 # 00 # 00 # 00 # 6F # 01 # 3F # 04 # 00 # 0A # 1A 10 Unsuccessful automatic ignition # 07 # 00 # 00 # 00 # 1F # 01 # DF # 04 # 00 # 0A # 1A 10 Number of trips thermal protection # 07 # 00 # 00 # 00 # 20 # 01 # A1 # 04 # 00 # 00 # 10 0 Outdoor temperature # 07 # 00 # 00 # 00 # 6A # 03 # 37 # 06 # 00 # FC # 39 # AA # 63 -60.44 T-pa boiler SC down # 07 # 00 # 00 # 00 # B6 # 02 # 97 # 06 # 00 # FF # 21 # AA # 5F -13.94 T ra feed # 07 # 00 # 00 # 00 # 18 # 03 # D3 # 06 # 00 # 01 # 76 # 00 # 88 23.38 / no errors Start the timer by GVL # 07 # 00 # 00 # 00 # 71 # 01 # 03 # 04 # 00 # 01 # 11 1 (ON) Mode # 07 # 00 # 00 # 00 # 08 # 01 # F1 # 04 # 00 # 01 # 11 1 (winter) Request to heat DHW C1 / C2 # 07 # 00 # 00 # 00 # 58 # 01 # 51 # 04 # 00 # 00 # 10 0 (OFF) Ionisation current # 07 # 00 # 00 # 00 # 73 # 02 # 04 # 05 # 00 # FC # EC # 25 64748.00 Circulation pump for boiler layered # 07 # 00 # 00 # 00 # E0 # 01 # 38 # 04 # 00 # 00 # 10 0 (OFF) Pumps UK # 07 # 00 # 00 # 00 # DF # 01 # 46 # 04 # 00 # 00 # 10 0 (OFF) The circulation pump # 07 # 00 # 00 # 00 # AF # 01 # A6 # 04 # 00 # 00 # 10 0 (OFF) Pump heating boiler # 07 # 00 # 00 # 00 # 01 # 9E # C4 # 04 # 00 # 00 # 10 0 (OFF) External heating pump # 07 # 00 # 00 # 00 # 3F # 01 # 9F # 04 # 00 # 00 # 10 0 (OFF) Built-in pump # 07 # 00 # 00 # 00 # 44 # 01 # 69 0 (OFF) Calc. temp an external regulator 7-8-9 # 07 # 00 # 00 # 00 # 25 # 02 # A8 # 05 # 00 # 05 # A0 # 82 90,00 Room thermostat # 07 # 00 # 00 # 00 # 01 # 0E # FD # 04 # 00 # 00 # 10 0 (OFF) The design temperature of the boiler # 07 # 00 # 00 # 00 # 04 # 02 # EA # 05 # 00 # 00 # F0 # D8 15 degrees The calculated flow temperature, the handle on the panel # 07 # 00 # 00 # 00 # 19 # 02 # D0 # 05 # 00 # 02 # 30 # 1C 35 degrees The temperature of the boiler # 07 # 00 # 00 # 00 # 17 # 03 # CD # 06 # 00 # FF # 21 # AA # 5F -13.94 Degrees The flow sensor HS # 07 # 00 # 00 # 00 # 16 # 03 # CF # 06 # 00 # FF # 21 # AA # 5F -13.94 Record the values in the boiler: The second byte is 0x80 The fifth byte - Register Sixth byte - value Seventh - CRC (checksum) Example, set the value of the pump run - 31 minutes (value 0x1F) Register 0x64 # 07 # 80 # 00 # 00 # 64 # 1F # FF If all goes well, the boiler will return the following sequence. # 03 # 00 # 06 |