<?xml version="1.0" encoding="UTF-8"?>

<rss version="2.0"
 xmlns:blogChannel="http://backend.userland.com/blogChannelModule"
>

<channel>
<title><![CDATA[Dobrica Pavlinušić's random unstructured stuff: ZPH02-PM2.5]]></title>
<link>https://saturn.ffzg.hr/rot13/index.cgi?zph02_pm2_5</link>
<description></description>
<pubDate>Sun, 29 Sep 2019 14:44:02 -0000</pubDate>
<webMaster>root@saturn.ffzg.hr</webMaster>
<generator>Socialtext Workspace v2.19.0.2</generator>

<item>
<title><![CDATA[ZPH02-PM2.5]]></title>
<link>https://saturn.ffzg.hr/rot13/index.cgi?zph02_pm2_5</link>
<description><![CDATA[<div>Creator: Dobrica Pavlinušić</div><hr/><div>Tags: air quality</div><hr/><div class="wiki">
<span class="nlw_phrase"><a href="https://saturn.ffzg.hr/rot13/index.cgi/ZPH02.pdf?action=attachments_download;page_name=zph02_pm2_5;id=20190924131858-1-3848">ZPH02.pdf</a><!-- wiki: {file: ZPH02.pdf} --></span><br /><br /><p>
<a target="_blank" title="(external link)" href="http://git.rot13.org/?p=air-quality;a=blob;f=zph02.pl;hb=HEAD">http://git.rot13.org/?p=air-quality;a=blob;f=zph02.pl;hb=HEAD</a></p>
<h1 id="technical_parameters">Technical Parameters</h1>
<p>
Model ZPH02<br />
Working voltage range 5 +/- 0.2 V (DC)<br />
Output way Rate of low level%(recommending 30s)<br />
Output signal voltage 5 +/- 0.2 V<br />
Detection ability smallest particles 1 μm diameter<br />
Warm-up time<br />
Working current<br />
Storage<br />
Humidity<br />
≤1min(device warming-up time)<br />
≤90mA<br />
≤95%RH<br />
range Working ≤95%RH<br />
Temperature<br />
range Storage<br />
Working -30 deg. C~50 deg. C<br />
0�C~50�C<br />
Size 59.5�44.5�20mm(L�W�H)<br />
Physical interface EH2.54-5P</p>
<h1 id="pinout">pinout</h1>
<table style="border-collapse: collapse;" class="formatter_table">
<tr>
<td style="border: 1px solid black;padding: .2em;">PIN No.</td>
<td style="border: 1px solid black;padding: .2em;">PMW mode</td>
<td style="border: 1px solid black;padding: .2em;">UART mode</td>
</tr>
<tr>
<td style="border: 1px solid black;padding: .2em;">PIN1</td>
<td style="border: 1px solid black;padding: .2em;">GND</td>
<td style="border: 1px solid black;padding: .2em;">GND</td>
</tr>
<tr>
<td style="border: 1px solid black;padding: .2em;">PIN2</td>
<td style="border: 1px solid black;padding: .2em;">NC</td>
<td style="border: 1px solid black;padding: .2em;">TXD</td>
</tr>
<tr>
<td style="border: 1px solid black;padding: .2em;">PIN3</td>
<td style="border: 1px solid black;padding: .2em;">VCC</td>
<td style="border: 1px solid black;padding: .2em;">VCC</td>
</tr>
<tr>
<td style="border: 1px solid black;padding: .2em;">PIN4</td>
<td style="border: 1px solid black;padding: .2em;">PWM</td>
<td style="border: 1px solid black;padding: .2em;">NC</td>
</tr>
</table>
<br />| PIN5 | NC | Connects to GND | 
</div>
<hr/><div>Attachments: ZPH02.pdf</div>]]></description>
<author>Dobrica Pavlinu&#x161;i&#x107;</author>
<category>air quality</category>
<guid isPermaLink="true">https://saturn.ffzg.hr/rot13/index.cgi?zph02_pm2_5</guid>
<pubDate>Sun, 29 Sep 2019 14:44:02 -0000</pubDate>
</item>
</channel>
</rss>